STREAM.80

Membrane Nitrogen Generator for LCMS

Reference | STREAM.80
Nitrogen
LC-MS, Sample evaporation, TURBOVAP

The Membrane Nitrogen generator has been developed to meet specific requirements in terms of flow, purity and pressure for LC-MS applications. It can also be used for the evaporation of solvents in samples being analysed.
The simple high efficiency membrane technology allows the separation of nitrogen from the other components of the compressed air inlet.

stream-80-nitrogen-generator

Advantages product

IMPROVE LABORATORY EFFICIENCY

The relatively high gas volumes required by LCMS instruments
make cylinder supply inappropriate for such applications. A
constant, uninterrupted gas supply eliminates interruptions
of analyses to change cylinders.

IMPROVE ANALYTICAL INSTRUMENTS PERFORMANCE

Production of a constant flow of gas improves the
consistency of the analysis results and hence reproducibility.

IMPROVE ECONOMY

- Quick return on investment < 1 year
- No gas cylinder rental bottles, no price inflation

IMPROVE SAFETY

Nitrogen produced at low pressure and ambient temperature
removes the hazards associated with high pressure cylinders
and liquid Dewarโ€™s

SIMPLE INSTALLATION

Gas generators can be installed in the laboratory, on or
under a bench, eliminating the need for long gas lines from
cylinders secured elsewhere. No power supply is require.

Characteristics

 Flow rate available : 80 to 220 L/min
 Low pressure loss : max 1 bar (14 psi)
 Wall mounted installation : save space in the lab
 No noise : no mechanical parts moving
 No need of electricity supply
 Low maintenance : only to replace the filters once per year
 Gas saving mode : the unit stops automatically when nitrogen is not required

Specifications

Models
STREAM.80
GENERALS INFORMATIONS
Max Flow rate
80 to 220 L/min
Purity
99% – 97%
Max pressure outlet
7 bar (101 psi)
Pressure loss
< 0.8 bar (12 psi)
Air inlet pressure Min./Max.
5 -13 bar (72 – 188 psi) (see correction factor))
N2 dewpoint at operating pressure
-40ยฐC (-40ยฐF)
Particles
< 0.01 ppm
Air flow rate required @ 8 bar (116 psi)
280 L/min
Air loss for regeneration
28 L/min
Temperature range
From 5 – 25ยฐC (41 – 77ยฐF))
Dimensions
(W x H x D)
38 x 120 x 22.5 cm (15″ x 47″ x 9″)
Weight (kg/lbs)
26 / 57
CONNECTIONS
Inlet/outlet
1/4 G
FACTOR OF CORRECTION
Pressure (bar)
5
6
7
8
9
10
11
12
13
Pressure (psi)
72
87
101
116
130
145
159
174
188
Factor of correction
0.8
0.9
1.0
1.0
1.1
1.2
1.3
1.35
1.45

Multiply the nominal flow of the generator by the factor of correction which corresponds to the inlet pressure of the generator.

Download documentation

Disposer de toute lโ€™information nรฉcessaire pour mener ร  bien votre projet est fondamental, cโ€™est pourquoi nous vous mettons ร  disposition ces documents.

Nโ€™hรฉsitez pas ร  nous contacter pour toutes questions.

STREAM.80 - Data sheet (EN)
STREAM.80 - Setup guide
STREAM.80 - User manual

Quotation request

Your Name*
Your Email*
Your Phone*
Name of Company*
Your Role*
Your Country*
Interested in*
How did you hear about us?*
What is your request*
Your Message*